Overview
The Report Settings tab lets you customise investigation level settings, bioattenuation parameters, receptors, contaminants of potential concern (COPCs) and the Adopted Investigation Levels wording for a specific report. Any changes here override the site-level defaults for this report only - they do not affect the site configuration.
This tab only appears for report types that support override categories. If you do not see it, the report type does not have configurable settings.
Like every tab of the report, it shows the status bar and the Next action panel above the settings.
Before You Customise
Report settings are not customised by default. Until they are, the tab shows Report Settings Not Yet Customised: the report uses the site's settings (receptors, COPCs, and investigation level options) as they stand when each draft is generated.
Customise only if this report needs to differ from the site without changing the site itself. To do so, click Customise Now. The site's current settings are copied to the report, the editable form replaces the message, and from that point on the tab always shows the form.
If report settings differ from the site, a Report settings differ from site banner appears at the top listing the specific differences.
Weather Appendix (LFG SEM Event)
An LFG SEM Event report has a Weather Appendix section on this tab, saved with its own Save button and without customising any other settings.
By default the weather appendix holds the weather chart and a one-page daily weather observations summary for the 28 days before the monitoring day(s) and the monitoring day(s).
Tick Weather appendix: full station data (monitoring day and 28 days before) to print the full hourly station data for the same period instead of the summary.
Site Attribute Checkboxes
These checkboxes control how investigation levels and report calculations are applied for this report. They are organised into two groups, and which groups appear depends on what the report type supports. A given report type may show one group, both groups, or neither.
Adjusted Levels and Bioattenuation group:
Apply Adjusted Levels - Enables adjusted investigation levels.
Apply HSL Bioattenuation Factor - Enables the HSL bioattenuation factor and reveals additional settings (see below).
Investigation Level Flags group:
Account for Bioaccumulation - Includes bioaccumulation in calculations.
Apply Short Term Trigger Values - Includes short-term trigger values in the assessment.
Apply Long Term Trigger Values - Includes long-term trigger values in the assessment.
Exclude Low Reliability Values - Excludes values flagged as low reliability.
HSL Bioattenuation
This section appears when Apply HSL Bioattenuation Factor is ticked. All three conditions must be met and depth to groundwater must be at least 2 m for the factor to apply.
Is there evidence of oxygen penetration? - When ticked, sub-fields appear for Assessment Location, Oxygen Reading (%) (minimum 5%), and Oxygen Reading Depth (m) (minimum 1 m).
Is the hydrocarbon source depth 2 metres or deeper? - When ticked, a Justification field appears.
Does the concrete slab have one side less than 15 metres? - When ticked, sub-fields appear for Slab Length (m), Slab Width (m), and Slab Description.
Depth to Groundwater (m below ground surface) - 2 to 4 m applies a 10x factor. 4 m or more applies a 100x factor.
Unticking a condition checkbox clears its sub-fields when you save. Unticking Apply HSL Bioattenuation Factor hides and clears all of these answers.
Saving the Settings
Click Save to save the checkboxes and HSL bioattenuation answers.
Click Close to leave without saving.
Receptors, COPCs and the Adopted Investigation Levels wording are saved on their own views (below), each with its own Save.
Receptors & COPCs
For report types that support receptor and COPC overrides, the Receptors & COPCs section has two buttons. Each opens its own view inside the Report Settings tab, with a Back to Report Settings link at the top.
Adjust Site Receptors (this report only)
Receptors are shown for each fieldwork task type the report covers, grouped under each of the site's selected guidelines.
Receptors a guideline requires are listed with a lock icon. They are always included, on the site and on this report.
Optional receptors the site has selected have a checkbox. Untick any this report should leave out.
Each receptor shows its colour and group.
If the site has no guidelines selected for the report's fieldwork tasks, a message asks you to choose guidelines on the site's Guidelines and Receptors tab first.
Click Save to save the receptors.
Adjust Site COPCs (this report only)
COPCs are organised by matrix tabs (for example Soil, Groundwater). A badge on each tab shows how many analytes are selected.
Within each matrix, analytes are grouped by analyte group. Click a group's name to expand it, or use Expand All / Collapse All.
A group-level checkbox selects or deselects all analytes in a group at once.
Each analyte shows its CAS-RN, concentration type, and unit of measure.
Save saves the matrix tab on screen only. Save each matrix before switching tabs, because unsaved ticks are not kept when you switch.
Adopted Investigation Levels
For report types that use the Adopted Investigation Levels table, the Adopted Investigation Levels section has an Adjust Investigation Levels Table (this report only) button. It opens a view where you edit the wording of that table for this report:
Each row has a Matrix, Beneficial Use, Potential Receptors and Adopted Investigation Levels. Drag rows (or use the up and down arrows) to reorder them, use Add row to add one, and the remove button to delete one.
With no rows, the report shows "Not applicable".
Copy from site replaces the rows with the site's wording.
Click Save to save the rows. Changes here do not affect the site's wording.
Investigation Levels (Read-Only)
The Investigation Levels section at the bottom of the page shows the investigation levels that result from this report's receptors and COPCs. It is read-only and reflects your saved changes. Values marked "NL" indicate "Not Limiting" concentrations, and a dash means no investigation level is available for that analyte and receptor.
Reset to Site Values
The Reset to Site Values button overwrites all report-level customisations with the current site values. A confirmation prompt appears ("Reset all report settings to current site values? This will overwrite any customisations.") before the reset is applied. This cannot be undone.
Things to Know
If the site settings are correct for this report, you do not need to customise anything.
Receptor, COPC and Adopted Investigation Levels changes are saved on their own views, separately from the main Save button.
The difference banner at the top is a quick way to see where this report deviates from the site.
Not every report type shows both checkbox groups. If you only see a subset, the missing checkboxes are not supported by this report type.
An approved Asbestos Clearance Certificate's settings are read only ("This Asbestos Clearance Certificate has been approved and can no longer be changed. Create a new certificate to issue a correction.").
If your organisation has the AI assistant switched on, you can also ask the report chat to make these changes (customise the settings, set the report's COPCs or receptors, or save the Adopted Investigation Levels rows). Each change comes as a card you approve. See Using AI in Client Reports.
Whether a result equal to the investigation level counts as an exceedance, and whether less-than-LOR results are flagged, are not set here. They are set on the report's Client Report Configuration (see Client Reports: Exceedance and Non-Detect Settings).