What this tutorial covers
A step-by-step walkthrough of the SEM Remediation Event Log form in the EnviroAutomate app. Use this to record the work you've done to remediate point source methane exceedances found during the previous LFG SEM Event. The exceedance list is pre-populated from that event - you work through each one. Each Take Photos button on this form opens a page where you can take a new photo or upload one from your device.
Before you start
Open the EnviroAutomate app while you have signal so the exceedance list downloads.
Have your gas meter, calibration certificate, remediation kit and PPE ready.
Calibrate the meter against fresh standards before you arrive on site.
Step 1 - Open the task
Open the EnviroAutomate app and tap Inbox.
Tap your dispatched SEM Remediation task.
Tap Start Form Task.
Step 2 - Landfill SEM Exceedance Remediation Log (header)
Confirm Project Code, Site Name and Site Address are correct (these are read-only).
Type the Meter Make / Model.
Tap Take Photos under Calibration Certificates and add the cert for your gas meter.
Step 3 - Open the exceedance list
Tap Surface Emission Remediation Log. The number next to it shows how many point sources are queued for remediation.
A list of Point Source Code entries opens on its own screen - one per open point source from the prior SEM event. A point source found on a transect shows the Point Source ID typed on the SEM form followed by the exceedance date (for example PS-01-20261113); a fixed point source shows its location code. Point sources that have already been remediated, or whose location is inactive, are not listed. Don't tap Delete next to an entry unless you mean to remove that point source from this log.
Step 4 - Work through each point source
For each point source on the list:
Tap the Point Source Code entry to open it. The Point Source Code, Point Source Maximum Methane (ppm) - Pre-Remediation, Exceedance Date, GPS Eastings and GPS Northings are pre-filled and read-only, and the Point Source Type (penetration/defect/feature) is already selected - check them so you know what you're walking up to.
Walk to the GPS location and locate the point source. Confirm the Point Source Type matches what you see on the ground.
Carry out the remediation (re-seal cap, replace gas well cap, fill defect, etc.).
Point Source Location Remediation Completed? starts on No. The fields that appear next depend on its setting:
No: type the Reason Remediation Not Completed (required, e.g. "infrastructure penetration - referred to engineering").
Yes (switch it on): pick the Remediation Completed Date, type Remediation Completed By (your name or the contractor's), pick the Post Remediation Reading Date, and type the Maximum Methane (ppm) - Post Remediation (the new reading you took at the same point after fixing it). All four are required.
Tap Take Photos under Remediation Photo and add a before / after or completed photo (optional).
Tap Done to save the entry. You're back on the point source list.
Tap the next Point Source Code entry and repeat.
Step 5 - Submit
When every point source has been actioned, tap Submit.
After you submit
The submission is matched to the SEM Remediation fieldwork task in EnviroAutomate. Each point source's outcome and the photos you took are recorded against the Site. A point source found on a transect whose remediation is recorded is set to inactive, so it drops off later remediation lists.
Tips
If you can't locate a point source on the ground (markers worn, GPS drift), leave Point Source Location Remediation Completed? on No and put a note in Reason Remediation Not Completed so it carries forward to the next event.
Use Save and Exit if you need to break between sources.